Repair a Leaking Cast Iron Pipe

Repair a Leaking Cast Iron Pipe

Learn more about SteelStik

Seal a crack or pinhole in a cast iron drain or vent pipe with J-B Weld SteelStik, a steel-reinforced epoxy putty. Stop using the drain, wire-brush the pipe to bare metal, dry it, then press the kneaded putty over the leak. It sets in 5 minutes and cures in an hour. Wrap a long crack with a FiberWeld 2-inch pipe repair cast. Badly rusted or flaking pipe should be replaced.

Difficulty
Moderate
Working time
40 min
Cure time
Sets in 5 min, full cure 1 hr
Works on
Cast ironMetal

How to repair a leaking cast iron pipe

  1. Step 1: Stop the flow

    Don't use any drains above the leak while you work.

  2. Step 2: Wire-brush to bare metal

    Wire-brush and sand around the leak until you reach solid, bare metal.

  3. Step 3: Dry and degrease

    Wipe the area clean and let it dry completely.

  4. Step 4: Cut

    Remove required amount of putty.

  5. Step 5: Mix

    Thoroughly knead putty with fingers to a uniform color.

  6. Step 6: Press it over the leak

    Press the putty firmly into and over the crack, overlapping onto solid pipe.

  7. Step 7: Wrap a long crack (optional)

    For a long crack, wrap a FiberWeld 2-inch pipe repair cast over the putty.

  8. Step 8: Let it cure

    Let it cure a full hour before you use the drain again.

What you'll need

J-B Weld products

Tools and materials

  • Wire brush
  • Sandpaper
  • Rags
  • Bucket
  • Gloves

Frequently asked questions

Can SteelStik be applied to a damp or wet surface?

No. SteelStik needs a dry surface and must stay dry until it cures. Shut off the water, dry the area, sand it to clean bare metal, and wipe it with acetone before applying. It sets in about 5 minutes and cures in an hour. Once fully cured it can be exposed to water. If the surface cannot be dried, use WaterWeld (8277) instead.

Can SteelStik be drilled, tapped and painted?

Yes. After it cures, SteelStik can be drilled, tapped, machined, ground, filed, sanded and painted, and it cures dark gray. Wipe it with acetone before painting; enamel spray gives a good finish. It will not take chrome plating or powder coating, because it does not conduct current. Where you need clean, reusable machined threads, PlasticBonder (50139) taps better than SteelStik.

What pipe materials does the 2" FiberWeld cast bond to?

Metal and plastic pipe, including copper, cast iron, galvanized steel, PVC and ABS, plus non-metal pipe such as terra cotta. The surface must be clean, dry and scuffed, since it grips a textured surface far better than a smooth one. Press the epoxy putty into the leak first and wrap over it rather than relying on the wrap alone to seal.

Can I use the 2" FiberWeld cast on a high-pressure or steam line?

No. The 500 PSI figure is a water pressure rating for plumbing, not a rating for pump discharge, hydraulic or steam service, and J-B Weld does not publish a temperature rating for this wrap. A hairline crack on the pressure side of a pump needs to be TIG welded; an epoxy or wrap repair there will blow out under load.

Other repairs using SteelStik Epoxy Putty